Study finds US water systems security even weaker than believed
A Securin study of 236 water technology vendors found nearly twice as many vulnerabilities as public records, plus 20 exploited flaws absent from CISA's KEV catalog.
A study of 236 technology vendors that supply equipment to US drinking water, wastewater, and industrial water systems found that American water systems are less secure than previously believed. The Water Supply Chain Watch index from exposure management firm Securin identified nearly twice as many vulnerabilities as public records listed, including 20 exploited flaws not found in CISA's Known Exploited Vulnerabilities catalog. Researchers compared vendor data with records from CISA, EPA, FBI, and WaterISAC, using CISA advisory data through November 20 and KEV entries through November 23.
Advisory volume and vendor concentration
The federal government has issued 4,014 security advisories for industrial control systems and cataloged 1,792 vulnerabilities known to have been exploited in cyberattacks. Federal water advisories reached their highest level this year since 2020. Five vendors, Rockwell Automation with 58, Advantech with 48, Schneider Electric with 35, Siemens with 26, and ABB with 24, account for 191 of 376 water-tagged security advisories. Advantech had the highest number of critical vulnerabilities, but none of the CVEs in its advisories appear in CISA's KEV catalog. Unitronics had only two water-tagged advisories, yet at least 75 of its controllers were compromised between November 2023 and January 2024 through default or missing passwords.
Real-world attacks often skip software bugs
The report also points to a gap between water-related CVEs and real-world attacks, which do not always require attackers to exploit software bugs. In July, attackers suspected to be linked to Iran targeted more than 100 water systems across at least 12 states, using poorly secured internet-connected controllers. According to Securin, 791 Rockwell MicroLogix 1400 controllers across multiple industries in the US were exposed to the internet as of November 17. Forescout research cited by Securin found that seven in 10 exposed Rockwell controllers in the US sit on mobile carrier networks, where poorly secured cellular modems can provide an entry point.
Cellular modems and recommended defenses
A July CISA advisory describes Iranian-affiliated APT actors using foreign-based IP addresses to access internet-facing PLCs made by Rockwell Automation/Allen-Bradley, Schneider Electric, Siemens, and potentially other manufacturers. The actors used leased, third-party hosted infrastructure and manufacturers' PLC programming software to connect to misconfigured victim PLCs, with inbound malicious traffic targeting PLC ports 44818, 2222, 102, and 502, and modems on port 22. These cellular modems are often installed by third-party contractors and frequently are not documented. Securin's top recommendation is for utilities to find every cellular modem, including contractor-installed units, ensure they are not exposed to the open internet, and place a gateway with multifactor authentication in front of them. Securin CEO Srinivas Mukkamala said utilities spend time and money fixing vulnerabilities they are told to worry about, while attackers get in through equipment nobody knew was connected or passwords nobody bothered to change.
Sources: The Register
SiTech — AI-powered web development